MTA grilles unlike the MT grilles are not equipped with the flange.
INDEX
interior dim. (mm)
exterior dim. (mm)
characteristics
a
b
x
y
fly-net
include
colour
MTA2B
120
120
165
165
+
4 pins
white
MTA4B
120
185
165
240
+
4 pins
white
MTA6B
150
150
195
195
+
4 pins
white
MTA8B
195
195
250
250
+
4 pins
white
MTA10B
245
245
295
295
+
4 pins
white
MTA12B
85
250
125
295
+
4 pins
white
MTA2AN
120
120
165
165
+
4 pins
antique
MTA4AN
120
185
165
240
+
4 pins
antique
MTA6AN
150
150
195
195
+
4 pins
antique
MTA8AN
195
195
250
250
+
4 pins
antique
MTA10AN
245
245
295
295
+
4 pins
antique
MTA12AN
85
250
125
295
+
4 pins
antique
MTA2ANSR
120
120
165
165
+
4 pins
antique silver
MTA4ANSR
120
185
165
240
+
4 pins
antique silver
MTA6ANSR
150
150
195
195
+
4 pins
antique silver
MTA8ANSR
195
195
250
250
+
4 pins
antique silver
MTA10ANSR
245
245
295
295
+
4 pins
antique silver
MTA12ANSR
85
250
125
295
+
4 pins
antique silver
MTA2N
120
120
165
165
+
4 pins
stainless
MTA4N
120
185
165
240
+
4 pins
stainless
MTA6N
150
150
195
195
+
4 pins
stainless
MTA8N
195
195
250
250
+
4 pins
stainless
MTA10N
245
245
295
295
+
4 pins
stainless
MTA12N
85
250
125
295
+
4 pins
stainless
RETIS/INSIDE Series
interior dim. (mm)
exterior dim. (mm)
outlet (mm)
length of flange (mm)
description
INDEX
a
b
x
y
Ø
z
fly-net
TR (Retis)
153
153
172
172
125
30
+
TI (Inside)
153
153
175
175
125
30
-
Round Elastic Channels
INDEX
section (mm)
length (running meter)
KE100-10
Ø100
1,00
KE100-30
Ø100
3,00
KE100-60
Ø100
6,00
KE125-10
Ø125
1,00
KE125-30
Ø125
3,00
KE125-60
Ø125
6,00
KE150-10
Ø150
1,00
KE150-30
Ø150
3,00
KE150-60
Ø150
6,00
Flat Elastic Channels
INDEX
section (mm)
length (running meter)
KE55-10
55x110
1,00
KE55-30
55x110
3,00
KE55-60
55x110
6,00
KE75-10
75x150
1,00
KE75-30
75x150
3,00
KE75-60
75x150
6,00
Round Duct Reduction - multistage
INDEX
Ø1 (mm)
Ø2 (mm)
Ø3 (mm)
Ø4 (mm)
Ø5 (mm)
RKO
100
110
120
125
150
AWENTIS II
AWENTIS II is used when one or two rooms are to be ventilated.
Advantages from operating the AWENTIS system:
• The ventilation process is not stopped if the ventilator is off (e.g. during a blackout) because the air is continually exchanged through the screened opening (gravitational ventilation). • The ventilator does not need to be switched on for the ventilation system to operate properly. Lower electricity bills and total silence are undeniable advantages. • The ventilator may be switched on and used instead of the screened duct if the air is to be exchanged more quickly. • Unfavorable atmospheric conditions may render the gravitational ventilation useless. The ventilator may be switched on to ensure proper operation of the ventilation system.
Fan
Ventilation grille
Kitchen
exhaust system
System AWENTIS II is offered in sets that contain - except of accessories necessary for each set (grates, ventilators) - also elements necessary to finish all assembly works (e.g.: two sections of channels with 12 cm length, masks suitable for the given set and plaster boards).
An example of usage AWENTIS II equipped with a ventilation grille and conected with an oven-hood.
AWENTIS II is sold in the following sets:
II/A - basic set consisting of a body, two 12 cm long ducts, two PVC covers (20 x 20 cm and 20 x 30 cm) and plaster boards; II/B - basic set with an additional ventilator RETIS WR125 (with a connection block) and ventilation screen TR; II/BT - basic set with an additional ventilator RETIS WR125 (with a connection block and a timer) and ventilation screen TR; II/C - basic set with an additional ventilator INSIDE WI125 (with a connection block) and ventilation screen TI; II/CT - basic set with an additional ventilator INSIDE WI125 (with a connection block and a timer) and ventilation screen TI.
AWENTIS II fulfills its task perfectly when installed inside ventilation hood. When the ventilation hood is on, natural ventilation goes through ventilation channel with grate and once the device is on, the exhausted air will not return to the kitchen by the same channel because the sprocket of the System will close the way.
The following graph shows another use of the AWENTIS II System in which the body is fitted with ventilation grate (outlet in to bedroom) and the exhaust fan is installed in the bathroom.
AWENTIS I is used when a single room is to be ventilated.
Advantages from operating the AWENTIS system:
• The ventilation process is not stopped if the ventilator is off (e.g. during a blackout) because the air is continually exchanged through the screened opening (gravitational ventilation).
• The ventilator does not need to be switched on for the ventilation system to operate properly. Lower electricity bills and total silence are undeniable advantages.
• The ventilator may be switched on and used instead of the screened duct if the air is to be exchanged more quickly.
• Unfavorable atmospheric conditions may render the gravitational ventilation useless. The ventilator may be switched on to ensure proper operation of the ventilation system.
Fan
Ventilation grille
Kitchen
exhaust system
System AWENTIS I is offered in sets that contain - except of accessories necessary for each set (grates, ventilators) - also elements necessary to finish all assembly works (e.g.: two sections of channels with 12 cm length, masks suitable for the given set and plaster boards).
An example of usage AWENTIS I equipped with an exhaust fan and a ventilation grille in a single room:
AWENTIS I is sold in the following sets:
I/A - basic set consisting of a body, two 12 cm long ducts, 20 x 40 cm PVC cover with metal plate and a plaster board; I/B - basic set with an additional ventilator RETIS WR125 (with a connection block) and ventilation screen TR; I/BT - basic set with an additional ventilator RETIS WR125 (with a connection block and a timer) and ventilation screen TR; I/C - basic set with an additional ventilator INSIDE WI125 (with a connection block) and ventilation screen TI; I/CT - basic set with an additional ventilator INSIDE WI125 (with a connection block and a timer) and ventilation screen TI.
Practical use of the system AWENTIS I in bathrooms: